Hydro-Mix XT Flush Mount Moisture Sensor
Connections
The Hydro-Mix XT is a flush mount moisture sensor that can be connected to a control system in 2 ways: analogue and digital. The RS485 serial interface allows up to 16 sensors to connect directly to a control system via a serial communications link. There are 2 analogue outputs which can be configured to 4-20mA, 0-20mA (0-10V), 1 configurable digital input and 1 configurable digital input / output. These different options provide the system integrator with the flexibility to select the most suitable method of connecting to their control system.
There are various options for interfacing between the sensor and the control system using a Hydronix approved Ethernet, USB or RS232/RS485 adapter. Alternatively, the Hydro-View moisture display can be used to provide real time on-line process measurements including both moisture and temperature. In it's simplest configuration the analogue output from the Hydro-Mix can be connected to a Scaleable Current Loop Display to display the current moisture.
Hydro-Mix XT Connections Options

Input / Output Connections

Cabling
The Hydro-Mix XT has an integrated 4m cable for termination in a junction box enabling the sensor signal to be sent to a Control System or PC for configuration and calibration.
Recommended field cabling:
- Six pairs twisted (12 cores total) screened (shielded) cable with 22 AWG, 0.35mm2 conductors
- Screen (shield): Braid with 65% minimum coverage plus aluminium/polyester foil
- Recommended cable types: Belden 8306, Alpha 6373
- Maximum recommended cable run: 100m, separate to any heavy equipment power cables