Installation Points:
- Panel mount or enclosure fixing
Unique Key Features:
- Stand alone unit designed for the accurate addition of water into a mixer.
- 10.1" LCD colour display touch screen.
- Different operating modes for each recipe.
- Over 99,000 recipes can be stored.
- Suitable for new and retrofit systems. 
- Designed to work with all common forms of water addition to a mixer.
- System integration - ethernet, WEB API and RS232 communication.
- Remote connection for diagnostics and support.
- Digital Technology
- Digital technology provides precise, linear moisture measurement.
- Advanced Digital Signal Processing
- The sensor response may be adjusted remotely using the Hydro-Com software to minimise the effects of noise of the measured signal. Advanced Digital Signal Processing provides a clear signal with a rapid response.
- Measurement Modes
- Choice of measurement modes for optimising sensor performance in a variety of applications and material types (except Hydro-Probe).
- Fully Temperature Compensated Measurement
- The sensor internally adjusts for mechanical changes due to temperature fluctuations
- Easy to Interface
- Two analogue outputs and digital RS485 communications and configurable digital inputs / output make the sensor simple to integrate into a control system. Includes Modbus.
- Fast Measurement
- Measuring at 25 times per second, the sensor continuously detects changes in the moisture of the materials throughout processing.
- Temperature Measurement
- Temperature output is available to provide a readout of material temperature.
- Accuracy of Measurement
- All measurements can be calibrated to an accuracy of 0.2% for aggregates (0.1% in the mixer) and 0.5% for other materials.
- Sensor Configuration
- Sensors can be remotely configured using Hydro-Com diagnostic software or Hydro-View/Hydro-Hub. All readings and sensor parameters are available including the type of output and filtering characteristics.
- Calibration
- The sensor may be internally calibrated using Hydro-Com software, or the linear output may be calibrated within the control system or remotely by using the Hydronix Hydro-View/Hydro-Hub interfaces.
- Simple Power Requirements
- The sensor may be powered from a 15-30V dc supply. Multiple sensors may be driven from a single power source.
 
                                
                                    Modbus to control system                                
                             
                                
                                    Input / Output connections                                
                                
                                    Recommended field cabling:
                                    
                            - Six pairs twisted (12 cores total) screened (shielded) cable with 22 AWG, 0.35mm2 conductors
- Screen (shield): Braid with 65% minimum coverage plus aluminium/polyester foil
- Recommended cable types: Belden 8306, Alpha 6373
- Maximum cable run: 100m, separate to any heavy equipment power cables
 
                    	                 
                                                 
                                                 
                                                 
                                                 7025 HC07 Replacement System Card
 7025 HC07 Replacement System Card 7050 Hydro-Control Model HC06 to HC07 adapter plate
 7050 Hydro-Control Model HC06 to HC07 adapter plate 7060 Hydro-Control Model HC06 to HC07 adapter cable
 7060 Hydro-Control Model HC06 to HC07 adapter cable 7100 HC07 Wall Mounting Enclosure for Hydro-Control Unit IP66 (NEMA4)
 7100 HC07 Wall Mounting Enclosure for Hydro-Control Unit IP66 (NEMA4) 7200 HC07 Control Cabinet (pre-wired for easy connection to field wiring)
 7200 HC07 Control Cabinet (pre-wired for easy connection to field wiring) 
                                     
                                     
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                