Hydronix logo
Digital Microwave Moisture Measurement for Concrete, Asphalt and Process Industries from Hydronix

Comprising a single, intelligent unit that contains all on-board functionality including signal processing and averaging, the Hydro-Mix XT-FS accurately measures the moisture content of material passing over the ceramic faceplate.

Hydro-Mix XT-FS surface installation

Installation

The sensor has a flange mounting to allow installation onto the fixing plate and seals with an O-Ring.

The sensor has an integrated 4m cable which is prepared to terminate in a junction box or other suitable panel.

Installation into Hoppers, Mixers or Conveyors

The Hydro-Mix XT-FS can be mounted in many different locations where there is a continuous flow of material across the ceramic faceplate. These include hoppers, ducting, conveyors and mixer systems.

Single/Twin Shaft Mixers

Hydro-Mix XT-FS Moisture Sensor in a single and twin shaft mixer

The Hydro-Mix XT-FS should ideally be positioned on the end wall of the mixer, 30° from vertical and on the upstroke of the blade.

Hoppers

Hydro-Mix XT-FS Moisture Sensor in a single and twin shaft mixer

Screw Conveyors

Moisture sensor in screw conveyor

The Hydro-Mix XT-FS is positioned on the upstroke of the blade at 30° from vertical.