Installation Points:
- Unit can be installed in an operator panel or in the Hydronix steel enclosure.
Unique Key Features:
- 10.1" touch screen system to view data and manage Hydronix Sensors.
- Connects a network of up to 16 Hydronix sensors with multiple systems simultaneously.
- Easy to install in new or existing systems
- Live display to view measurements of up to 6 sensors.
- Calibrate and configure Hydronix sensors remotely.
- 256 calibrations per sensor.
- Ethernet Port with web browser interface / Web API.
- Digital Technology
- Digital technology provides precise, linear moisture measurement.
- Advanced Digital Signal Processing
- The sensor response may be adjusted remotely using the Hydro-Com software to minimise the effects of noise of the measured signal. Advanced Digital Signal Processing provides a clear signal with a rapid response.
- Measurement Modes
- Choice of measurement modes for optimising sensor performance in a variety of applications and material types (except Hydro-Probe).
- Fully Temperature Compensated Measurement
- The sensor internally adjusts for mechanical changes due to temperature fluctuations
- Easy to Interface
- Two analogue outputs and digital RS485 communications and configurable digital inputs / output make the sensor simple to integrate into a control system. Includes Modbus.
- Fast Measurement
- Measuring at 25 times per second, the sensor continuously detects changes in the moisture of the materials throughout processing.
- Temperature Measurement
- Temperature output is available to provide a readout of material temperature.
- Accuracy of Measurement
- All measurements can be calibrated to an accuracy of 0.2% for aggregates (0.1% in the mixer) and 0.5% for other materials.
- Sensor Configuration
- Sensors can be remotely configured using Hydro-Com diagnostic software or Hydro-View/Hydro-Hub. All readings and sensor parameters are available including the type of output and filtering characteristics.
- Calibration
- The sensor may be internally calibrated using Hydro-Com software, or the linear output may be calibrated within the control system or remotely by using the Hydronix Hydro-View/Hydro-Hub interfaces.
- Simple Power Requirements
- The sensor may be powered from a 15-30V dc supply. Multiple sensors may be driven from a single power source.
 
                                
                                    Modbus to control system                                
                             
                                
                                    Input / Output connections                                
                                
                                    Recommended field cabling:
                                    
                            - Six pairs twisted (12 cores total) screened (shielded) cable with 22 AWG, 0.35mm2 conductors
- Screen (shield): Braid with 65% minimum coverage plus aluminium/polyester foil
- Recommended cable types: Belden 8306, Alpha 6373
- Maximum cable run: 100m, separate to any heavy equipment power cables
 
                    	                 
                                                 
                                                 
                                                 
                                                 1175 HV05 Wall Mount Enclosure
 1175 HV05 Wall Mount Enclosure 1187 PROFIBUS Module
 1187 PROFIBUS Module 1189 PROFINET Module
 1189 PROFINET Module 1188 Ethernet/IP Module
 1188 Ethernet/IP Module 1190 Digital Input Expansion Card
 1190 Digital Input Expansion Card 
                                     
                                     
                                     
                                     
                                     
                                     
                                     
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                