Hydronix Cement Savings Report

Company Name
Binis Banja Luka
Contact Name
Laboratorija 1 Binis
Date
17 septiembre, 2026
A link to this report was emailed to laboratorija.binis@binisbeton.com
A batching plant has to design mixes based around historic results. A statistical analysis of the results can then be made and a result called the Standard Deviation (SD) gives the spread of the results around a mean value. British and EU law states that the design strength of the concrete mix must be at a point that is 2x Standard Deviations below the mean value. This means that the probability of batches will be below the design strength is only approximately 2.275%.
So a 38 N/mm2 with a W/C ratio of 0.605 and a water quantity of 200 l/m3 would need 331kg of cement. A 34N/mm2 mix has a W/C ratio of 0.660 and so will only need 303kg of cement presuming the water demand is constant. This still gives the same design strength of C30 but saves 28kg of cement per m3!
  Potential (worst case) uncompensated water
Material Your Recipe (Dry Weights) Using existing measurement tolerance (Automatic) With Hydronix
Fine Sand 0 - 2mm 540 5.40 1.08
Coarse Sand 0 - 4mm 540 5.40 1.08
Gravel 8 - 16mm 517 5.17 1.03
Other Aggregates 222 2.22 0.44
Weight of uncompensated moisture 0 18.19 3.64
Total Weight 1819 1837 1823
OPC 340 0.00 0.00
PFA 0 0.00 0.00
GGBS 0 0.00 0.00
Other Cement Replacements 0 0.00 0.00
Total Cementitious Materials (Binder) 340 340 340
Mix design water (litres) 191.00 191.00 191.00
uncompensated Water in Aggregates (litres) 0.00 18.19 3.64
Total Water in mix (litres) 191.00 209.19 194.64
Designed W/C ratio 0.56 0.56 0.56
Produced W/C ratio 0.62 0.57
Total Cement Needed to maintain SD target 372.38 346.48
Extra cement needed to maintain SD target 32.38 6.48
Potential cement cost by not using Hydronix moisture measurement   25.90 kg/m3
Extra Cement required to maintain w/c ratio per year   647.60 Tonnes
Cost of not using Hydronix per m3 £/$/€ 2.07
Cost of not using Hydronix per year £/$/€ 51,808.168
Environmental Cost of not using Hydronix per year 600,974.74 kgCO2e/t

Related Articles

Moisture Measurement – an Essential for Automating Concrete Production

The current worldwide health challenges are causing many organisations to adjust their working practices to minimise the staff involved in a site whilst still managing full production schedules. Automation is…

Leer más

Capturing and using moisture measurement data: ‘Big Moisture’

For many industries, measurement and control of the moisture in materials is vital. Whether it be adding the incorrect amount of water spoils the product or over-drying it wastes energy,…

Leer más