{"id":1186,"date":"2022-03-22T12:35:00","date_gmt":"2022-03-22T12:35:00","guid":{"rendered":"https:\/\/hydronix.chilliservers.co.uk\/?p=614"},"modified":"2025-09-15T14:59:11","modified_gmt":"2025-09-15T14:59:11","slug":"capturing-and-using-moisture-measurement-data-big-moisture","status":"publish","type":"post","link":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/","title":{"rendered":"Capturing and using moisture measurement data: \u2018Big Moisture\u2019"},"content":{"rendered":"    <div class=\"container-xl\">\n\t\t\n<p>For many industries, measurement and control of the moisture in materials is vital. Whether it be adding the incorrect amount of water spoils the product or over-drying it wastes energy, moisture measurement matters. Within a larger process, moisture monitoring and correction often needs to happen at different stages because the moisture content before and after each sub-process can be critical to the quality of the final product.<br>Achieving the balance right requires instantaneous, online access to moisture data throughout the process. Moisture content of materials entering and exiting processes can change rapidly, requiring an instant response to maintain the quality of the final product and the efficiency of the process.<br>Online moisture measurement offers scope for immense benefits, including:<\/p>\n    <\/div>\n    \n\n\n<ul class=\"wp-block-list\">\n<li>Optimisation of recipes to efficiently use raw materials<\/li>\n\n\n\n<li>Cutting the amount of spoiled material<\/li>\n\n\n\n<li>Lowering energy costs<\/li>\n\n\n\n<li>Reducing processing time<\/li>\n\n\n\n<li>Increasing production rates<\/li>\n\n\n\n<li>Higher quality and greater consistency in end products<\/li>\n\n\n\n<li>Maximising profitability<\/li>\n<\/ul>\n\n\n    <div class=\"container-xl pt-4\" id=\"the-need-for-connectivity\">\n        \n<h2 class=\"wp-block-heading\">The need for connectivity<\/h2>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Today, digital moisture sensors that offer highly accurate, real-time data are commonly deployed throughout processes. This avoids the need for manual laboratory testing and enables automated control of moisture. Customers are increasingly demanding real-time connected solutions and wish to use networking technologies to connect all their sensors to the plant\u2019s monitoring and control system.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Consolidating the data from all the moisture sensors throughout the plant and making this information available online and accessible from anywhere, ensures not only that individual processes can be monitored and maintained but that interacting processes may be monitored and the entire plant optimised in real-time. Historic data can also be easily collated and compared to other plants to review and improve efficiencies across the breadth of the company.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"monitoring-sensor-performance\">\n        \n<h2 class=\"wp-block-heading\">Monitoring Sensor Performance<\/h2>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>If the data from sensors is to be trusted, it is important to be able to monitor and assess the sensors\u2019 performance. Smart sensors must include remote access and built-in diagnostics data to ensure that issues affecting measurement such as blockages or damage to the sensor can be quickly identified and rectified.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"bridging-the-gap-between-plant-and-office\">\n        \n<h2 class=\"wp-block-heading\">Bridging the gap between plant and office<\/h2>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>The centralisation of critical moisture data ensures that process engineers always have a current view of precise process conditions and allows the control system to respond rapidly and automatically to correct any issues or improve performance.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Using online data, stored either locally or in the cloud, it is possible to record, monitor and analyse the data over time, allowing trends to be identified and further improvements to plant performance to be achieved. If the organisation has several plants, performance can be further improved by comparing the data for each of them.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"requirements-for-connecting-sensors\">\n        \n<h2 class=\"wp-block-heading\">Requirements for connecting sensors<\/h2>\n    <\/div>\n    \n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"678\" src=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-connectivity-1024x678.png\" alt=\"\" class=\"wp-image-10637\" srcset=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-connectivity-1024x678.png 1024w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-connectivity-300x199.png 300w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-connectivity-768x508.png 768w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-connectivity-1536x1017.png 1536w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-connectivity.png 2000w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n    <div class=\"container-xl\">\n\t\t\n<p>Hydronix Sensors have numerous ways of connecting to the plant control systems. The most basic systems use the sensors\u2019 analogue loop output. More advanced systems use the selectable Modbus option, a protocol running on RS485, designed to deliver optimum performance in a manufacturing environment. The sensors can also connect using various other industrial communication protocols.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Most people are used to hearing of the Internet of Things (IoT) and Ethernet TCP\/IP for connecting devices to the web and between homes and offices, the Industrial Internet of Things (IIoT) enables the same types of connection in a far more robust, secure, and controllable manner.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Because of the different standards used for data communication between industrial and home or office environments, connecting industrial sensors online requires a bridge between the two different types of networks to facilitate the connection and ensure the security of both systems.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"easy-connectivity\">\n        \n<h2 class=\"wp-block-heading clearfix\">Easy connectivity<\/h2>\n    <\/div>\n    \n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"678\" src=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-Inter-connectivity-1024x678.png\" alt=\"\" class=\"wp-image-10640\" srcset=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-Inter-connectivity-1024x678.png 1024w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-Inter-connectivity-300x199.png 300w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-Inter-connectivity-768x508.png 768w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-Inter-connectivity-1536x1017.png 1536w, https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/Hydronix-Network-Plant-Inter-connectivity.png 2000w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n    <div class=\"container-xl\">\n\t\t\n<p>The Hydronix&nbsp;<a href=\"\/products\/hydro-hub\/\">Hydro-Hub<\/a>\u2122 is a solution that provides a bridge to easily transfer moisture data between industrial and office-based IT networks. Designed to add flexibility and to future-proof existing and new investments, it ensures that all industries that rely on accessing moisture data can benefit from the advantages of connected Hydronix sensors.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>The Hydro-Hub acts as the central point to connect up to 16 sensors simultaneously to online systems with an Ethernet connection. Multiple Hydro-Hubs may be deployed across a local, or wide area network, to connect devices within a single plant and from various plants around the world. It offers an easy method of moisture data collection, sensor configuration, diagnostics, and calibration selection.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>To simplify the access to the sensor data, a built-in web server allows direct access from a tablet or PC, while a web API interface provides for remote connections to data storage and online plant management or monitoring systems.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>The&nbsp;<a href=\"\/products\/hydro-view\/\">Hydro-View<\/a>&nbsp;is a similar product that additionally incorporates a 10.1\u201d touchscreen to view and interact with the sensors. The Hydro-View allows sensor integration with a control system and also connection to IT systems as well as being a standalone unit for recording sensor data.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"conclusion\">\n        \n<h2 class=\"wp-block-heading clearfix\">Conclusion<\/h2>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>As with other process control parameters, effective moisture control relies upon accessing reliable, high quality, real-time data. Network-enabled devices give the industry the tools to monitor and adjust plant-wide variables with very significant benefits including, savings in energy carbon footprint, maintenance, and material costs.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>To help industries achieve these benefits, leading sensor manufacturers, such as Hydronix, provide highly accurate sensors with networking technology, high-quality training materials as well as global support and service.<\/p>\n    <\/div>\n    \n\n\n<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-155830380347\"\n  style=\"max-width:100%; max-height:100%; width:210px;height:42.390625px\" data-hubspot-wrapper-cta-id=\"155830380347\">\n  <a href=\"https:\/\/cta-eu1.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLI20o1JfRf%2FZntCnwstINKUnti7gOE3Zwd0Ps89jcHHLlyLUiVmUanAe1cNrxZtziL2TsApDpxP46czLq1oCo9jWB8eGX4tFj6MdHtigGPFaOklIFc%2FscgivZ9h48aetoMtvxALy4A524s%2B2QexCahdWpgNPVqU%2Fz3STfHdlTU193nRFT6JOXaMkWwLSwG1RfzVemL2Mg%3D%3D&#038;webInteractiveContentId=155830380347&#038;portalId=8142423\" target=\"_blank\" rel=\"noopener\" crossorigin=\"anonymous\">\n    <img decoding=\"async\" alt=\"Speak to an Expert\" loading=\"lazy\" src=\"https:\/\/hubspot-no-cache-eu1-prod.s3.amazonaws.com\/cta\/default\/8142423\/interactive-155830380347.png\" style=\"height: 100%; width: 100%; object-fit: fill\"\n      onerror=\"this.style.display='none'\" \/>\n  <\/a>\n<\/div>\n\n\n\n    <div class=\"container-xl\">\n\t\t\n<p><a href=\"https:\/\/info.hydronix.com\/blog\/capturing-and-using-moisture-measurement-data\/#\"><\/a><\/p>\n    <\/div>\n    ","protected":false},"excerpt":{"rendered":"<p>For many industries, measurement and control of the moi [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\">Read More&#8230;<span class=\"screen-reader-text\"> from Capturing and using moisture measurement data: \u2018Big Moisture\u2019<\/span><\/a><\/p>\n","protected":false},"author":3,"featured_media":10642,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","inline_featured_image":false,"footnotes":""},"categories":[56],"tags":[],"class_list":["post-1186","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Capturing and using moisture measurement data: \u2018Big Moisture\u2019<\/title>\n<meta name=\"description\" content=\"How to use connected sensors to capture, analyse and interpret moisture measurement data to optimise your processes.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Capturing and using moisture measurement data: \u2018Big Moisture\u2019\" \/>\n<meta property=\"og:description\" content=\"How to use connected sensors to capture, analyse and interpret moisture measurement data to optimise your processes.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\" \/>\n<meta property=\"og:site_name\" content=\"Hydronix\" \/>\n<meta property=\"article:published_time\" content=\"2022-03-22T12:35:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-15T14:59:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"659\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Neal Cass\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"Neal Cass\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\"},\"author\":{\"name\":\"Neal Cass\",\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a\"},\"headline\":\"Capturing and using moisture measurement data: \u2018Big Moisture\u2019\",\"datePublished\":\"2022-03-22T12:35:00+00:00\",\"dateModified\":\"2025-09-15T14:59:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\"},\"wordCount\":864,\"image\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\",\"url\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\",\"name\":\"Capturing and using moisture measurement data: \u2018Big Moisture\u2019\",\"isPartOf\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg\",\"datePublished\":\"2022-03-22T12:35:00+00:00\",\"dateModified\":\"2025-09-15T14:59:11+00:00\",\"author\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a\"},\"description\":\"How to use connected sensors to capture, analyse and interpret moisture measurement data to optimise your processes.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage\",\"url\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg\",\"contentUrl\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg\",\"width\":1200,\"height\":659},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hydronix.com\/zh-hans\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Capturing and using moisture measurement data: \u2018Big Moisture\u2019\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/#website\",\"url\":\"https:\/\/www.hydronix.com\/zh-hans\/\",\"name\":\"Hydronix\",\"description\":\"Your partner in moisture measurement\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hydronix.com\/zh-hans\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hydronix.com\/zh-hans\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a\",\"name\":\"Neal Cass\",\"description\":\"After gaining his degree in Electronic Engineering from the University of Southampton in England, Neal spent 10 years developing and commissioning control systems for a major international food process system manufacturer. In 2007 he started working for Hydronix as a Customer Service and Software Development Engineer before becoming Sales Manager in 2011. In February 2025, Neal joined the Board of Directors as Sales Director. Neal is responsible for sales strategy across the business.\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Capturing and using moisture measurement data: \u2018Big Moisture\u2019","description":"How to use connected sensors to capture, analyse and interpret moisture measurement data to optimise your processes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/","og_locale":"zh_CN","og_type":"article","og_title":"Capturing and using moisture measurement data: \u2018Big Moisture\u2019","og_description":"How to use connected sensors to capture, analyse and interpret moisture measurement data to optimise your processes.","og_url":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/","og_site_name":"Hydronix","article_published_time":"2022-03-22T12:35:00+00:00","article_modified_time":"2025-09-15T14:59:11+00:00","og_image":[{"width":1200,"height":659,"url":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg","type":"image\/jpeg"}],"author":"Neal Cass","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"Neal Cass","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"5 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#article","isPartOf":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/"},"author":{"name":"Neal Cass","@id":"https:\/\/www.hydronix.com\/zh-hans\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a"},"headline":"Capturing and using moisture measurement data: \u2018Big Moisture\u2019","datePublished":"2022-03-22T12:35:00+00:00","dateModified":"2025-09-15T14:59:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/"},"wordCount":864,"image":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg","articleSection":["Blog"],"inLanguage":"zh-Hans"},{"@type":"WebPage","@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/","url":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/","name":"Capturing and using moisture measurement data: \u2018Big Moisture\u2019","isPartOf":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage"},"image":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg","datePublished":"2022-03-22T12:35:00+00:00","dateModified":"2025-09-15T14:59:11+00:00","author":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a"},"description":"How to use connected sensors to capture, analyse and interpret moisture measurement data to optimise your processes.","breadcrumb":{"@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#primaryimage","url":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg","contentUrl":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2022\/03\/shutterstock_1913078362-water-connectivity_medium.jpg","width":1200,"height":659},{"@type":"BreadcrumbList","@id":"https:\/\/www.hydronix.com\/zh-hans\/resources\/blogs\/capturing-and-using-moisture-measurement-data-big-moisture\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hydronix.com\/zh-hans\/"},{"@type":"ListItem","position":2,"name":"Capturing and using moisture measurement data: \u2018Big Moisture\u2019"}]},{"@type":"WebSite","@id":"https:\/\/www.hydronix.com\/zh-hans\/#website","url":"https:\/\/www.hydronix.com\/zh-hans\/","name":"Hydronix","description":"Your partner in moisture measurement","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hydronix.com\/zh-hans\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/www.hydronix.com\/zh-hans\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a","name":"Neal Cass","description":"After gaining his degree in Electronic Engineering from the University of Southampton in England, Neal spent 10 years developing and commissioning control systems for a major international food process system manufacturer. In 2007 he started working for Hydronix as a Customer Service and Software Development Engineer before becoming Sales Manager in 2011. In February 2025, Neal joined the Board of Directors as Sales Director. Neal is responsible for sales strategy across the business."}]}},"_links":{"self":[{"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/posts\/1186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=1186"}],"version-history":[{"count":2,"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/posts\/1186\/revisions"}],"predecessor-version":[{"id":41637,"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/posts\/1186\/revisions\/41637"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/media\/10642"}],"wp:attachment":[{"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=1186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=1186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hydronix.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=1186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}