{"id":41990,"date":"2025-12-02T12:06:40","date_gmt":"2025-12-02T12:06:40","guid":{"rendered":"https:\/\/www.hydronix.com\/?p=41990"},"modified":"2025-12-02T17:39:50","modified_gmt":"2025-12-02T17:39:50","slug":"relative-vs-absolute-values-for-control","status":"publish","type":"post","link":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/","title":{"rendered":"Precision Without Complexity: The Power of Relative Values for Control"},"content":{"rendered":"    <div class=\"container-xl pt-4\" id=\"introduction\">\n        \n<h3 class=\"wp-block-heading\">Introduction<\/h3>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Modern industrial processing relies heavily on automation. <a href=\"https:\/\/www.hydronix.com\/moisture-measurement\/\">Moisture <\/a>is one of the most influential variables in many production processes. Manual direct testing is time-consuming, and results often take hours to obtain. This delay prevents real-time process control. Inline sensors calibrated to laboratory methods enhance responsiveness; however, calibrating every material or recipe can be time-consuming and impractical.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>In automated systems, control loops adjust process parameters to maintain a target condition. Importantly, they do not need the absolute moisture value to do this. What they need is a measurement that is stable and repeatable. When a sensor provides a consistent signal, the controller can react reliably to whether the material is wetter or drier than expected. This makes controlling to relative values highly attractive, delivering effective automation without the complexity of calibration.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"why-moisture-measurement-enables-automation\">\n        \n<h3 class=\"wp-block-heading\">Why Moisture Measurement Enables Automation<\/h3>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Automated systems make continuous adjustments to maintain consistent material behaviour and dry\u2011matter content. Moisture can fluctuate with the season, storage and preprocessing environment. Manual determination of moisture can take hours, and adjustments to the process cannot be made in real-time, resulting in imprecise measurements. Inline sensors enable real-time correction. Calibrating the sensor to real (absolute) moisture values still takes time, and this can become burdensome in processes that use many different recipes.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"absolute-vs-relative-values\">\n        \n<h3 class=\"wp-block-heading\">Absolute vs Relative Values<\/h3>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Absolute moisture values represent the actual percentage of water in the material. Achieving this requires extensive sampling, laboratory testing, and careful calibration, and it is sensitive to changes in components and their proportions. It is valuable when a finished product must meet a precise specification and is primarily useful for quality control and record-keeping.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Relative values, in contrast, use the sensor output as a consistent indicator of change. It is not tied to a laboratory reference value and so does not require detailed calibration. For automated control, repeatability is what matters most. This is the sensor&#8217;s ability to reliably indicate whether the material is wetter or drier than its target.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"why-material-conditioning-does-not-require-absolute-moisture-for-control\">\n        \n<h3 class=\"wp-block-heading\">Why Material Conditioning Does Not Require Absolute Moisture for Control?<\/h3>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>When conditioning materials, the objective is to maintain consistent conditions, ensure predictable behaviour during processing, and achieve high-quality final products. In water addition processes, if incoming material is wetter than usual, the system reduces water addition; if it is drier, it increases it. Similarly, in drying processes, if the incoming material is wetter, it increases the drying time, and if it is drier, it reduces the drying time. A repeatable relative measurement provides the precise feedback a Control loop needs. The Controller uses this signal to make corrections, ensuring steady-state performance without the need for constant retuning and recalibration.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"how-hydronix-sensors-facilitate-controlling-to-relative-values\">\n        \n<h3 class=\"wp-block-heading\">How Hydronix Sensors Facilitate Controlling to Relative Values<\/h3>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Hydronix digital microwave sensors provide the stable, repeatable measurement required for automated control. They are simple to set up and use, require minimal maintenance, and remain dependable even when material colour, particle size, surface moisture, or dust levels vary. Their long\u2011term signal stability reduces recalibration requirements, and they can be installed in mixers, conveyors, ducts, bins, and silos, making them easy to integrate throughout the production line.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"machine-learning-the-next-level-of-control\">\n        \n<h3 class=\"wp-block-heading\">Machine Learning: The Next Level of Control<\/h3>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Machine learning enhances relative value control by analysing historical process behaviour and predicting how values (and therefore moisture) will change under different conditions. ML\u2011enhanced systems can anticipate disturbances, adjust control parameters proactively, minimise manual intervention, and compensate automatically for raw\u2011material variability. This leads to more consistent production, better energy efficiency, and fewer process interruptions.<\/p>\n    <\/div>\n    \n\n    <div class=\"container-xl pt-4\" id=\"conclusion\">\n        \n<h3 class=\"wp-block-heading\">Conclusion<\/h3>\n    <\/div>\n    \n\n    <div class=\"container-xl\">\n\t\t\n<p>Absolute moisture measurement has its place, but automated control in production does not depend on it. Automation requires repeatable, real\u2011time insight. Relative measurement provides precisely that. Combined with the long-term stability of Hydronix sensors and the predictive power of machine learning, the future of production is more intelligent control, fewer manual corrections, and more time freed up for operators to focus on value-added work.<\/p>\n    <\/div>\n    \n\n\n<div class=\"hs-cta-embed hs-cta-simple-placeholder hs-cta-embed-314062587119\"\n  style=\"max-width:100%; max-height:100%; width:210px;height:42.390625px\" data-hubspot-wrapper-cta-id=\"314062587119\">\n  <a href=\"https:\/\/cta-eu1.hubspot.com\/web-interactives\/public\/v1\/track\/redirect?encryptedPayload=AVxigLKleXx739bcakdj6XMPZV1S1pZj5wmhP%2FLvjPdU3DgqjwjxiRacgNGvf9n%2F4VrCrh4EjvjDp9pcSk91eLz4SsNAENetOZxDHR1NSf2dsMU3LaFePBfn5sB8n92IkJDhYkL1zoi43EdSArnqt%2Fou%2BcLHhx9lrEehdbsWvBcysT19Ig1EbmTWU06K9IY2IL3mm8%2FISTQrLQ%3D%3D&#038;webInteractiveContentId=314062587119&#038;portalId=8142423\" target=\"_blank\" rel=\"noopener\" crossorigin=\"anonymous\">\n    <img decoding=\"async\" alt=\"Speak to an Expert\" loading=\"lazy\" src=\"https:\/\/hubspot-no-cache-eu1-prod.s3.amazonaws.com\/cta\/default\/8142423\/interactive-314062587119.png\" style=\"height: 100%; width: 100%; object-fit: fill\"\n      onerror=\"this.style.display='none'\" \/>\n  <\/a>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n    <div class=\"container-xl pt-4\" id=\"related-engineering-notes\">\n        \n<h5 class=\"wp-block-heading\">Related Engineering Notes:<\/h5>\n    <\/div>\n    \n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2024\/11\/en0077_1_3_0.pdf\">Batching Moisture Control Methods, EN0077<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/11\/en0114_1_0_0.pdf\">Combining feedforward and feedback control to optimise the performance of continuous moisture conditioning systems, EN0114<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Automated processing doesn\u2019t need exact moisture percentages\u2014it needs reliable, repeatable signals. Relative values allow control loops to react instantly without complex calibration. With Hydronix sensors providing stable measurement and machine learning enhancing predictions, producers gain smarter, more consistent automation with less manual intervention. [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\">\u0427\u0438\u0442\u0430\u0442\u044c \u0434\u0430\u043b\u044c\u0448\u0435\u2026<span class=\"screen-reader-text\"> from Precision Without Complexity: The Power of Relative Values for Control<\/span><\/a><\/p>\n","protected":false},"author":3,"featured_media":41991,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","inline_featured_image":false,"footnotes":""},"categories":[56],"tags":[1493,1450,1452,1494],"class_list":["post-41990","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-control-process","tag-moisture-control","tag-moisture-measurement","tag-process-automation"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Precision Without Complexity: The Power of Relative Values for Control - Hydronix<\/title>\n<meta name=\"description\" content=\"Control processes don\u2019t require absolute moisture values. Discover how repeatable relative measurements, Hydronix sensors, and machine learning transform automation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Precision Without Complexity: The Power of Relative Values for Control - Hydronix\" \/>\n<meta property=\"og:description\" content=\"Control processes don\u2019t require absolute moisture values. Discover how repeatable relative measurements, Hydronix sensors, and machine learning transform automation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\" \/>\n<meta property=\"og:site_name\" content=\"Hydronix\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-02T12:06:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-02T17:39:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"706\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Neal Cass\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"Neal Cass\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u043c\u0438\u043d\u0443\u0442\u044b\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\"},\"author\":{\"name\":\"Neal Cass\",\"@id\":\"https:\/\/www.hydronix.com\/ru\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a\"},\"headline\":\"Precision Without Complexity: The Power of Relative Values for Control\",\"datePublished\":\"2025-12-02T12:06:40+00:00\",\"dateModified\":\"2025-12-02T17:39:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\"},\"wordCount\":671,\"image\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png\",\"keywords\":[\"control process\",\"moisture control\",\"moisture measurement\",\"process automation\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\",\"url\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\",\"name\":\"Precision Without Complexity: The Power of Relative Values for Control - Hydronix\",\"isPartOf\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png\",\"datePublished\":\"2025-12-02T12:06:40+00:00\",\"dateModified\":\"2025-12-02T17:39:50+00:00\",\"author\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a\"},\"description\":\"Control processes don\u2019t require absolute moisture values. Discover how repeatable relative measurements, Hydronix sensors, and machine learning transform automation.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage\",\"url\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png\",\"contentUrl\":\"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png\",\"width\":1200,\"height\":706,\"caption\":\"Precision Without Complexity: The Power of Relative Values for Control\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hydronix.com\/ru\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Precision Without Complexity: The Power of Relative Values for Control\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hydronix.com\/ru\/#website\",\"url\":\"https:\/\/www.hydronix.com\/ru\/\",\"name\":\"Hydronix\",\"description\":\"Your partner in moisture measurement\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hydronix.com\/ru\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hydronix.com\/ru\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a\",\"name\":\"Neal Cass\",\"description\":\"After gaining his degree in Electronic Engineering from the University of Southampton in England, Neal spent 10 years developing and commissioning control systems for a major international food process system manufacturer. In 2007 he started working for Hydronix as a Customer Service and Software Development Engineer before becoming Sales Manager in 2011. In February 2025, Neal joined the Board of Directors as Sales Director. Neal is responsible for sales strategy across the business.\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Precision Without Complexity: The Power of Relative Values for Control - Hydronix","description":"Control processes don\u2019t require absolute moisture values. Discover how repeatable relative measurements, Hydronix sensors, and machine learning transform automation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/","og_locale":"ru_RU","og_type":"article","og_title":"Precision Without Complexity: The Power of Relative Values for Control - Hydronix","og_description":"Control processes don\u2019t require absolute moisture values. Discover how repeatable relative measurements, Hydronix sensors, and machine learning transform automation.","og_url":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/","og_site_name":"Hydronix","article_published_time":"2025-12-02T12:06:40+00:00","article_modified_time":"2025-12-02T17:39:50+00:00","og_image":[{"width":1200,"height":706,"url":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png","type":"image\/png"}],"author":"Neal Cass","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"Neal Cass","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"4 \u043c\u0438\u043d\u0443\u0442\u044b"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#article","isPartOf":{"@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/"},"author":{"name":"Neal Cass","@id":"https:\/\/www.hydronix.com\/ru\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a"},"headline":"Precision Without Complexity: The Power of Relative Values for Control","datePublished":"2025-12-02T12:06:40+00:00","dateModified":"2025-12-02T17:39:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/"},"wordCount":671,"image":{"@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png","keywords":["control process","moisture control","moisture measurement","process automation"],"articleSection":["Blog"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/","url":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/","name":"Precision Without Complexity: The Power of Relative Values for Control - Hydronix","isPartOf":{"@id":"https:\/\/www.hydronix.com\/ru\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage"},"image":{"@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png","datePublished":"2025-12-02T12:06:40+00:00","dateModified":"2025-12-02T17:39:50+00:00","author":{"@id":"https:\/\/www.hydronix.com\/ru\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a"},"description":"Control processes don\u2019t require absolute moisture values. Discover how repeatable relative measurements, Hydronix sensors, and machine learning transform automation.","breadcrumb":{"@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#primaryimage","url":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png","contentUrl":"https:\/\/www.hydronix.com\/wp-content\/uploads\/2025\/12\/iStock-1330811086_water-droplets-small.png","width":1200,"height":706,"caption":"Precision Without Complexity: The Power of Relative Values for Control"},{"@type":"BreadcrumbList","@id":"https:\/\/www.hydronix.com\/ru\/resources\/blogs\/relative-vs-absolute-values-for-control\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hydronix.com\/ru\/"},{"@type":"ListItem","position":2,"name":"Precision Without Complexity: The Power of Relative Values for Control"}]},{"@type":"WebSite","@id":"https:\/\/www.hydronix.com\/ru\/#website","url":"https:\/\/www.hydronix.com\/ru\/","name":"Hydronix","description":"Your partner in moisture measurement","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hydronix.com\/ru\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/www.hydronix.com\/ru\/#\/schema\/person\/3d39f1fbccad0deaa6455c2065a6ff9a","name":"Neal Cass","description":"After gaining his degree in Electronic Engineering from the University of Southampton in England, Neal spent 10 years developing and commissioning control systems for a major international food process system manufacturer. In 2007 he started working for Hydronix as a Customer Service and Software Development Engineer before becoming Sales Manager in 2011. In February 2025, Neal joined the Board of Directors as Sales Director. Neal is responsible for sales strategy across the business."}]}},"_links":{"self":[{"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/posts\/41990","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/comments?post=41990"}],"version-history":[{"count":3,"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/posts\/41990\/revisions"}],"predecessor-version":[{"id":42003,"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/posts\/41990\/revisions\/42003"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/media\/41991"}],"wp:attachment":[{"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/media?parent=41990"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/categories?post=41990"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hydronix.com\/ru\/wp-json\/wp\/v2\/tags?post=41990"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}