MEASURING
IN THE FLOW
The
Hydro-Probe II is designed to measure
continuously in the flow of material during batching. Reading at
25 times per second the sensor detects rapid changes in moisture,
providing a linear digital or analogue output.
BATCH AVERAGING
The
'averaging' mode continuously provides the 'average' reading of
moisture from the start of reading to any time selected - normally
the closing of the hopper door. Averaging, bin empty alarms and
signal processing performed internally by sensor.
INCLINATION
OF MEASUREMENT FACE
Another
unique feature is the 'angling' of the sensor face plate to the
flow of the material thereby ensuring consistent compaction and
flow characteristics over the sensor face irrespective of whether
the bin is full or almost empty. The normal angle for sand is 30
degrees but may be easily adjusted to suit the flow characteristics
of any material.

|
|
CALIBRATION
One
point technique enables sensor to be readily calibrated on site.
Further calibration points may be taken to ensure highest possible
accuracy. The sensor may be internally calibrated using the
Hydro-Com software, or the linear output may be calibrated within the control
system or by use of the Hydronix Hydro-View calibration unit.
MATCHING
CHARACTERISTICS
Identical
output characteristics for all sensors means it is now possible
to swap out sensors without recalibration.
A simple
air and bucket of water test may be performed to ensure sensor is
performing correctly.
SIMPLE
POWER REQUIREMENTS
The
Hydro-Probe II may be powered from wide
range dc supply. Multiple sensors may be driven from a single power
source.
TEMPERATURE
MEASUREMENT
Temperature
output is available to provide read-out of material temperature.
|