MEASURING
IN THE MIXER
Reading
at 25 times per second the sensor detects rapid changes in the moisture
in the materials throughout the mix cycle.
SENSOR
CONFIGURATION
The
sensor is configured remotely using the Hydro-Com
diagnostic software. A large number of parameters are selectable,
including the type of output, filtering characteristics etc.
SENSOR
RESPONSE
The
sensor response may be adjusted remotely using the Hydro-Com
software to eliminate the effects of mixer blades and
air voids within the mix thereby ensuring optimum performance for
any particular type of mixer.
REPLACEABLE CERAMIC
Easily replaceable on site or by an OEM reseller, this is a fast and cost effective solution to minimise downtime and the inconvenience of a return to base repair.
GRAPHIC
DISPLAY
Using
the Hydro-Com software (or when interfacing
with other Hydronix equipment) a graphic trace may be viewed to
assist in selecting the most suitable set up parameters. This information
may also be used to determine the effectiveness of the mixing action
and whether any adjustments to the mixer configuration are required.
ACCURACY
OF MEASUREMENT
All
measurements may if required be calibrated to oven dried laboratory
tests to an accuracy of ± 0.1%.
|
|
SYNCHRONISED
READINGS
The
sensor may be programmed only to read after a given time period
after an input from (typically) a proximity switch that detects
a passing blade. This facility is useful when the sensor is covered
by material for only part of the mix cycle.
SENSOR
OUTPUTS
Two
modes of operation are selectable that change the sensor output.
1.
Standard mode: The sensor provides both a digital (serial) and analogue
linear output, that may be scaled internally or externally.
2.
Compatibility mode: The output simulates that of the previous range
of Hydronix analogue sensors, and is used when replacing this type
of sensor or when interfacing with the Hydro-View
or Hydro-Control IV units.
CALIBRATION
The
linear unscaled output requires calibration to provide a meaningful
moisture reading. When the sensor is connected directly to the control
system, calibration should be performed in the system, or alternatively
using Hydronix interface/control equipment. The facility to internally
calibrate the sensor using the Hydro-Com
software is also available.
TEMPERATURE
MEASUREMENT
Temperature
output is available to provide readout of material temperature.
WEAR
LIFE
The
ceramic faceplate is the only part exposed to wear when installed
in the mixer. The special composition of the material used has been
selected, after many years experience, for its exceptional wear
characteristics. Under normal use the sensor will last for many
years.
|