SUPPLY VOLTAGE
24v DC; and 15W for Hydro-Control V and Hydro-Mix V. Higher power may be required for powering valves and other outputs.

KEYBOARD
Sheet keyboard with polyester overlay.

GRAPHIC DISPLAY
120mm x 90mm1/4 VGA display with backlight.

RECIPES
Memory for 32 recipes.

SECURITY
Open access for operators; critical operations protected by two levels of pass codes.

COMMUNICATIONS
RS232 for connection to batch computer or remote recipe module or remote operator terminal. RS485 communications to Hydronix sensor.

SENSOR CONNECTION
The Hydro-Mix V Microwave Sensor is connected to the Hydro-Control V by 4 core screened cable. 16 x 0.2mm suitable for up to 100m. Longer cable runs require twisted pair signal cable.

OPERATING TEMPERATURE RANGE
0 -50 degrees C.

ELECTROMAGNETIC COMPATIBILITY
Meets the requirements of the Electromagnetic Compatibility Directive 89/336/EEC.

 

ACCESSORIES
Hydronix is able to recommend manufacturers of valves and water meters should they be required. Please contact us with your request

 

DIMENSIONS
Operator panel (for panel mounting):
Panel cut-out size 232mm wide x 178 mm high.

STEEL ENCLOSURE (Optional):
400mm wide by 400mm high by 200mm deep. Door hinged from left. IP65 rated.