SUPPLY
VOLTAGE
24v
DC; and 15W for Hydro-Control V and
Hydro-Mix V. Higher power may be required
for powering valves and other outputs.
KEYBOARD
Sheet
keyboard with polyester overlay.
GRAPHIC
DISPLAY
120mm
x 90mm1/4 VGA display with backlight.
RECIPES
Memory
for 32 recipes.
SECURITY
Open
access for operators; critical operations protected by two levels
of pass codes.
COMMUNICATIONS
RS232
for connection to batch computer or remote recipe module or remote
operator terminal. RS485 communications to Hydronix sensor.
SENSOR CONNECTION
The
Hydro-Mix V Microwave Sensor is connected
to the Hydro-Control V by 4 core screened
cable. 16 x 0.2mm suitable for up to 100m. Longer cable runs require
twisted pair signal cable.
OPERATING
TEMPERATURE RANGE
0
-50 degrees C.
ELECTROMAGNETIC
COMPATIBILITY
Meets
the requirements of the Electromagnetic Compatibility Directive
89/336/EEC.
ACCESSORIES
Hydronix
is able to recommend manufacturers of valves and water meters should
they be required. Please contact us
with your request
|