FUNCTION
The
mode of operation is simple in concept. The Hydro-Control
V progressively adds water to the mix until the moisture
target has been achieved. The target moisture is a nominal rather
than an absolute value, so no calibration is required.
The
parameters of the unique algorithm may be adjusted simply to ensure
optimum performance to suit the characteristics of any specific
mixer.
A
'Trim' function key enables manual intervention if required, and
is used when establishing the appropriate 'Moisture Target' for
any given mix recipe.
PROGRESSIVE
WATER ADDITION - FASTER MIXING CYCLE
The
Hydro-Control V's progressive water
control permits short 'Dry Mix' times (typically 10 seconds); reduces
time required to achieve homogeneity; reduces 'Wet Mix' time. Combined
with the linearity of the Hydro-Mix V,
this unique algorithm ensures optimum accuracy of final moisture.
WATER
METERING
It
is recommended (but not essential) that the system is used with
a water meter so that the quantity of water added may be displayed
in litres or gallons. A 'Reset' mode is available to ensure continued
production in case of sensor failure.
DISPLAY
INFORMATION
Navigation
through the system is intuitive. Normally the operator would only
use three screens:

The
'Mix Cycle' display indicates the progress in the mix cycle.

The
'Select Recipe' display.

The
'Edit Recipe' display.
Additional
screens will be used less frequently.
The
'System set up' screen is used in conjunction with the diagnostic
screens during commissioning.
The
'Diagnostic screens' provide direct communication with the Hydro-Mix
V sensor and enable the set up parameters within the sensor
to be viewed and changed.
|
|
MIX
SEQUENCE
A
typical mix cycle is illustrated below. After the aggregates and
cement have been loaded, a brief 'Dry Mix' period is followed by
'Final Wet'. During 'Final Wet' water is added progressively, using
the coarse and fine water feed until the moisture target for that
recipe has been reached. The 'Final Wet' is followed by the 'Wet
Mix', before 'Mix Complete' signifies the end of the cycle. Should
the moisture reading drop below a predetermined amount during 'Wet
Mix', then the system reverts to the 'Final Wet' phase and additional
water is added as required.

The
'Auto Track' facility may be enabled to ensure the mix is homogenous
prior to 'Mix Complete'. The parameters for Autotrack are configurable.
A
'Pre-wet' is available in which water is added to the aggregates
prior to the addition of cement.
RECIPES
99
recipes are available which may be selected locally via the Hydro-Control
V keypad or remotely using RS232 serial communication from
a plant PC or an optional remote recipe module. Recipes can also
be selected from a remote operator terminal. Please refer to 'Guidance
Notes - when ordering' for further details.
SECURITY
Access
to engineering or supervisor level information is password protected.
SYSTEM
INTERFACING
The
Hydro-Control V will operate as either
(1) a stand alone system where the mix cycle is started and reset
using the keypad function keys or a remote operator terminal (see
accessories); or (2) as an integral part of a fully automated system
using digital I/O for controlling the mix sequence steps, i.e. start/stop,
cement in etc.
Simulation
software - 'come play with me' This enables a PC to drive the Hydro-Control
V as though operating in a plant. All parameters may be selected
and changed and mix cycle sequences run as in a real installation.
This
is an invaluable tool, enabling operators to familiarise themselves
with the equipment without jeopardising production.
ORDERING
GUIDANCE NOTES
When
ordering, the relevant order codes should be specified. These notes
are to assist with the correct identification of the components
appropriate to your application. Please read these in conjunction
with the Technical Details, and the current price list prevailing
at the time. Items marked with an * are optional.
- The
standard system comprising the front panel unit (order code HC05
see main picture on front of this sheet). Input/output voltage
requirement MUST be specified at the time of ordering, either
90v - 140v AC, 180v - 280v AC or 2.5v - 28v DC.
- *The
units may be supplied installed in an IP65 steel enclosure unit.
- *A
30W DC power supply (0116) for sites without 24 V DC supply.
- *Remote
recipe selection module (8102) enables remote recipe selection
via digital inputs (not required when using serial communication).
-
*Remote operator terminal (8103) permits start/stop/pause/resume
and recipe selection away from Hydro-Control
V keypad.
|